Injection molding
PREPROCESSING
Drying recommended = Yes, if moisture content of resin exceeds recommended level
Drying temperature = 80°C
Drying time, dehumidified dryer = 2-4 h
Processing moisture content = <0.05 %
PROCESSING
Melt temperature optimum = 290°C
Melt temperature range = 280-300°C
Mould temperature optimum = 70°C
Mould temperature range = 50-90°C
Drying recommended = Yes, if moisture content of resin exceeds recommended level
Drying temperature = 80°C
Drying time, dehumidified dryer = 2-4 h
Processing moisture content = <0.05 %
PROCESSING
Melt temperature optimum = 290°C
Melt temperature range = 280-300°C
Mould temperature optimum = 70°C
Mould temperature range = 50-90°C
| Rheological properties | dry / cond | Unit | Test Standard | |
| Viscosity number | 280 / * | cm³/g | ISO 307, 1157, 1628 | |
| Moulding shrinkage, parallel | 1.4 / * | % | ISO 294-4, 2577 | |
| Moulding shrinkage, normal | 1.4 / * | % | ISO 294-4, 2577 |
| Mechanical properties | dry / cond | Unit | Test Standard | |
| Tensile Modulus | 3100 / 1200 | MPa | ISO 527-1/-2 | |
| Yield stress | 83 / 52 | MPa | ISO 527-1/-2 | |
| Yield strain | 5 / 27 | % | ISO 527-1/-2 | |
| Nominal strain at break | 40 / >50 | % | ISO 527-1/-2 | |
| Charpy impact strength | ISO 179/1eU | |||
| 23°C | N / N | kJ/m² | ||
| -30°C | N / N | kJ/m² | ||
| Charpy notched impact strength | ISO 179/1eA | |||
| 23°C | 6 / 20 | kJ/m² | ||
| -30°C | 5.5 / 4 | kJ/m² |
| Thermal properties | dry / cond | Unit | Test Standard | |
| Melting temperature, 10°C/min | 262 / * | °C | ISO 11357-1/-3 | |
| Glass transition temperature, 10°C/min | 70 / - | °C | ISO 11357-1/-2 | |
| Temp. of deflection under load | ISO 75-1/-2 | |||
| 1.8 MPa | 72 / * | °C | ||
| 0.45 MPa | 205 / * | °C | ||
| Vicat softening temperature, 50°C/h, 50N | 244 / * | °C | ISO 306 | |
| Coeff. of linear therm. expansion, parallel | 100 / * | E-6/K | ISO 11359-1/-2 | |
| Coeff. of linear therm. expansion, normal | 100 / * | E-6/K | ISO 11359-1/-2 | |
| Thermal conductivity of melt | 0.16 | W/(m K) | - | |
| Spec. heat capacity of melt | 2790 | J/(kg K) | - |
| Flammability | dry / cond | Unit | Test Standard | |
| Burning Behav. at 1.5mm nom. thickn. | HB / * | class | IEC 60695-11-10 | |
| Thickness tested | 1.5 / * | mm | IEC 60695-11-10 | |
| Burning Behav. at thickness h | V-2 / * | class | IEC 60695-11-10 | |
| Thickness tested | 3.0 / * | mm | IEC 60695-11-10 | |
| Oxygen index | 28 / * | % | ISO 4589-1/-2 |
| Electrical properties | dry / cond | Unit | Test Standard | |
| Relative permittivity | IEC 60250 | |||
| 100Hz | 4.3 / 10 | - | ||
| 1MHz | 3.6 / 4.2 | - | ||
| Dissipation factor | IEC 60250 | |||
| 100Hz | 150 / 2000 | E-4 | ||
| 1MHz | 150 / 750 | E-4 | ||
| Volume resistivity | 1E13 / 1E11 | Ohm*m | IEC 60093 | |
| Electric strength | 31 / - | kV/mm | IEC 60243-1 |
| Other properties | dry / cond | Unit | Test Standard | |
| Humidity absorption, 2mm | 2.6 / * | % | Sim. to ISO 62 | |
| Water absorption, 2mm | 8.5 / * | % | Sim. to ISO 62 | |
| Density | 1140 / - | kg/m³ | ISO 1183 | |
| Density of melt | 1010 | kg/m³ | - |